TRAKLOC® TLF Fixed Length Studs
TRAKLOC® Drywall Framing Systems
TRAKLOC® Steel Framing is a revolutionary development in cold-formed steel framing systems. Unlike traditional steel studs, which are cut to length for varying jobsite conditions, TRAKLOC® allows you to order one length member and "adjust" the length accordingly for variances in the slab. The stud consists of a traditional-style framing member combined with an interlocking adjustable component. The adjustable portion allows for telescopic length adjustments and can accommodate variances in the slab, and minor wall height differences.
Unit of Measure
Items |
/Asset/a1002.jpg 250TLF125-18 TRAKLOC® 0.0188 Inch (in) Design Thickness Fixed Length Stud |
/Asset/a1002.jpg 250TLF125-24 TRAKLOC® 0.0250 Inch (in) Design Thickness Fixed Length Stud |
/Asset/a1002.jpg 250TLF125-30 TRAKLOC® 0.0312 Inch (in) Design Thickness Fixed Length Stud |
/Asset/a1002.jpg 250TLF125-33 TRAKLOC® 0.0346 Inch (in) Design Thickness Fixed Length Stud |
/Asset/a1002.jpg 362TLF125-18 TRAKLOC® 0.0188 Inch (in) Design Thickness Fixed Length Stud |
|||||
Description | N/A The fixed length studs (TLF) are ordered to length, are single piece components, and are swaged at each end to interlock with the TRAKLOC® Track. This product is used in applications where the partition height is consistent and speed of installation is of critical importance. The unique swage at the end of each stud allows for quick, tight installation eliminating the need for framing screws or a lift/ladder to install the framing screws. | |||||||||
Brands | N/A A-1 Alloys ClarkDietrich® TRAKLOC® | |||||||||
Design Thickness | N/A 0.0188 in | N/A 0.0250 in | N/A 0.0312 in | N/A 0.0346 in | N/A 0.0188 in | |||||
Yield Strength | N/A 33 ksi | N/A 57 ksi | N/A 33 ksi | N/A 33 ksi | N/A 33 ksi | |||||
Area | N/A 0.102 in² | N/A 0.135 in² | N/A 0.167 in² | N/A 0.185 in² | N/A 0.123 in² | |||||
Weight | N/A 0.35 lb/ft | N/A 0.46 lb/ft | N/A 0.57 lb/ft | N/A 0.63 lb/ft | N/A 0.42 lb/ft | |||||
Gross Section Properties (lx) | N/A 0.106 in4 | N/A 0.139 in4 | N/A 0.171 in4 | N/A 0.188 in4 | N/A 0.248 in4 | |||||
Gross Section Properties (Sx) | N/A 0.084 in³ | N/A 0.111 in³ | N/A 0.137 in³ | N/A 0.151 in³ | N/A 0.137 in³ | |||||
Gross Section Properties (Rx)1 | N/A 1.017 in | N/A 1.014 in | N/A 1.011 in | N/A 1.010 in | N/A 1.419 in | |||||
Gross Section Properties (ly) | N/A 0.022 in4 | N/A 0.029 in4 | N/A 0.035 in4 | N/A 0.039 in4 | N/A 0.025 in4 | |||||
Gross Section Properties (Ry) | N/A 0.467 in | N/A 0.464 in | N/A 0.461 in | N/A 0.459 in | N/A 0.451 in | |||||
Effective Section Properties at Tensile Strength (Fy) (Ae) | N/A 0.056 in² | N/A 0.067 in² | N/A 0.113 in² | N/A 0.116 in² | N/A 0.056 in² | |||||
Effective Section Properties at Tensile Strength (Fy) (lx) | N/A 0.102 in4 | N/A 0.128 in4 | N/A 0.170 in4 | N/A 0.187 in4 | N/A 0.243 in4 | |||||
Effective Section Properties at Tensile Strength (Fy) (Sx) | N/A 0.070 in³ | N/A 0.086 in³ | N/A 0.125 in³ | N/A 0.143 in³ | N/A 0.091 in³ | |||||
Effective Section Properties at Tensile Strength (Fy) (Mal)2 | N/A 1387 in·lb | N/A 2921 in·lb | N/A 2475 in·lb | N/A 2824 in·lb | N/A 1797 in·lb | |||||
Effective Section Properties at Tensile Strength (Fy) (Mad)3 | N/A 1289 in·lb | N/A 2680 in·lb | N/A 2515 in·lb | N/A 3072 in·lb | N/A 1914 in·lb | |||||
Effective Section Properties at Tensile Strength (Fy) (Vag) | N/A 252 lb | N/A 596 lb | N/A 832 lb | N/A 990 lb | N/A 170 lb | |||||
Effective Section Properties at Tensile Strength (Fy) (Vanet) | N/A 198 lb | N/A 349 lb | N/A 388 lb | N/A 414 lb | N/A 165 lb | |||||
Stud/Track End Reaction (Rx) | N/A 40 lb | N/A 96 lb | N/A 106 lb | N/A 103 lb | N/A 53 lb | |||||
Torsional Properties (Jx1000) | N/A 0.0120 in4 | N/A 0.0281 in4 | N/A 0.0543 in4 | N/A 0.0738 in4 | N/A 0.0145 in4 | |||||
Torsional Properties (Cw) | N/A 0.031 in6 | N/A 0.040 in6 | N/A 0.049 in6 | N/A 0.053 in6 | N/A 0.068 in6 | |||||
Torsional Properties (Xo) | N/A -1.000 in | N/A -0.992 in | N/A -0.984 in | N/A -0.980 in | N/A -0.873 in | |||||
Torsional Properties (m) | N/A 0.598 in | N/A 0.594 in | N/A 0.590 in | N/A 0.587 in | N/A 0.540 in | |||||
Torsional Properties (Ro) | N/A 1.501 in | N/A 1.493 in | N/A 1.485 in | N/A 1.480 in | N/A 1.726 in | |||||
Torsional Properties (ß) | N/A 0.556 Beta | N/A 0.558 Beta | N/A 0.560 Beta | N/A 0.561 Beta | N/A 0.744 Beta | |||||
Length (Lu) | N/A 31.5 in | N/A 24.3 in | N/A 31.4 in | N/A 29.9 in | N/A 31.0 in | |||||
Width | N/A 2-1/2 in | N/A 2-1/2 in | N/A 2-1/2 in | N/A 2-1/2 in | N/A 3-5/8 in | |||||
Spacing | N/A 12 in16 in24 in | |||||||||
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 17 ft 2 in. | N/A 16 ft 10 in. | N/A 18 ft 5 in. | N/A 20 ft 11 in. | N/A 21 ft 7 in. | |||||
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 14 ft 5 in. | N/A 14 ft 10 in. | N/A 16 ft 0 in. | N/A 16 ft 7 in. | N/A 17 ft 11 in. | |||||
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 7 in. | N/A 13 ft 1 in. | N/A 14 ft 0 in. | N/A 14 ft 6 in. | N/A 15 ft 8 in. | |||||
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 14 ft 6 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 15 ft 0 in. | N/A 16 ft 2 in. | N/A 18 ft 3 in. | N/A 18-10 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 8 in. | N/A 13 ft 0 in. | N/A 14 ft 0 in. | N/A 14 ft 6 in. | N/A 15 ft 8 in. | |||||
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 11 ft 0 in. | N/A 11 ft 5 in. | N/A 12 ft 3 in. | N/A 12 ft 8 in. | N/A 13 ft 8 in. | |||||
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 7 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 13 ft 9 in. | N/A 14 ft 9 in. | N/A 16 ft 7 in. | N/A 16 ft 4 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 11 ft 6 in. | N/A 11 ft 10 in. | N/A 12 ft 8 in. | N/A 13 ft 2 in. | N/A 14 ft 3 in. | |||||
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 0 in. | N/A 10 ft 4 in. | N/A 11 ft 2 in. | N/A 11 ft 6 in. | N/A 12 ft 5 in. | |||||
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 15 ft 10 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 16 ft 8 in. | N/A 17 ft 6 in. | N/A 19 ft 0 in. | N/A 20 ft 0 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 13 ft 7 in. | N/A 13 ft 9 in. | N/A 15 ft 0 in. | N/A 15 ft 1 in. | N/A 16 ft 8 in. | |||||
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 11 ft 10 in. | N/A 12 ft 1 in. | N/A 13 ft 2 in. | N/A 13 ft 2 in. | N/A 14 ft 7 in. | |||||
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 13 ft 0 in. | N/A 14 ft 7 in. | N/A 15 ft 4 in. | N/A 16 ft 7 in. | N/A 16 ft 4 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 11 ft 10 in. | N/A 12 ft 0 in. | N/A 13 ft 1 in. | N/A 13 ft 2 in. | N/A 14 ft 7 in. | |||||
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 4 in. | N/A 10 ft 7 in. | N/A 11 ft 6 in. | N/A 11 ft 6 in. | N/A 12 ft 8 in. | |||||
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 11 ft 3 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 13 ft 3 in. | N/A 13 ft 11 in. | N/A 15 ft 1 in. | N/A 14 ft 1 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 9 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 10 ft 11 in. | N/A 11 ft 11 in. | N/A 12 ft 0 in. | N/A 13 ft 3 in. | |||||
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 9 ft 3 in. | N/A 9 ft 7 in. | N/A 10 ft 6 in. | N/A 10 ft 6 in. | N/A 11 ft 6 in. | |||||
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 13 ft 4 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 14 ft 10 in. | N/A 15 ft 9 in. | N/A 16 ft 7 in. | N/A 16 ft 4 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 12 ft 3 in. | N/A 12 ft 3 in. | N/A 13 ft 5 in. | N/A 13 ft 2 in. | N/A 14 ft 10 in. | |||||
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 10 ft 8 in. | N/A 10 ft 9 in. | N/A 11 ft 10 in. | N/A 11 ft 6 in. | N/A 13 ft 0 in. | |||||
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 10 ft 11 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 13 ft 0 in. | N/A 13 ft 9 in. | N/A 14 ft 6 in. | N/A 13 ft 4 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 10 ft 8 in. | N/A 10 ft 8 in. | N/A 11 ft 9 in. | N/A 11 ft 6 in. | N/A 13 ft 0 in. | |||||
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 9 ft 1 in. | N/A 9 ft 3 in. | N/A 10 ft 4 in. | N/A 10 ft 1 in. | N/A 11 ft 2 in. | |||||
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 9 ft 5 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 11 ft 9 in. | N/A 12 ft 6 in. | N/A 13 ft 2 in. | N/A 11 ft 6 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 9 ft 5 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 9 ft 8 in. | N/A 10 ft 8 in. | N/A 10 ft 6 in. | N/A 11 ft 6 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 11 in. | N/A 8 ft 2 in. | N/A 9 ft 3 in. | N/A 9 ft 0 in. | N/A 9 ft 10 in. | |||||
Notes for Composite Limiting Height |
N/A
|
|||||||||
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 13 ft 1 in. | N/A 15 ft 0 in. | N/A 16 ft 5 in. | N/A 17 ft 0 in. | N/A 15 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 11 ft 0 in. | N/A 11 ft 11 in. | N/A 13 ft 1 in. | N/A 13 ft 6 in. | N/A 14 ft 9 in. | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 8 in. | N/A 10 ft 5 in. | N/A 11 ft 5 in. | N/A 11 ft 9 in. | N/A 12 ft 10 in. | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 14 ft 9 in. | N/A 14 ft 10 in. | N/A 15 ft 10 in. | N/A 12 ft 8 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 8 in. | N/A 12 ft 10 in. | N/A 13 ft 3 in. | N/A 12 ft 8 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 6 in. | N/A 10 ft 3 in. | N/A 11 ft 3 in. | N/A 11 ft 7 in. | N/A 12 ft 8 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 13 ft 4 in. | N/A 12 ft 10 in. | N/A 13 ft 9 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 8 in. | N/A 11 ft 8 in. | N/A 12 ft 1 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 3 in. | N/A 10 ft 2 in. | N/A 10 ft 6 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 11 ft 4 in. (Web stiffeners are required at the stud/track connection.) | N/A 13 ft 7 in. | N/A 14 ft 11 in. | N/A 15 ft 5 in. | N/A 13 ft 5 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 0 in. | N/A 10 ft 10 in. | N/A 11 ft 10 in. | N/A 12 ft 3 in. | N/A 13 ft 4 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 9 in. | N/A 9 ft 5 in. | N/A 10 ft 4 in. | N/A 10 ft 8 in. | N/A 11 ft 8 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 9 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 13 ft 4 in. | N/A 12 ft 10 in. | N/A 13 ft 9 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 9 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 8 in. | N/A 11 ft 8 in. | N/A 12 ft 1 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 3 in. | N/A 10 ft 2 in. | N/A 10 ft 6 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 7 in. | N/A 11 ft 1 in. | N/A 11 ft 11 in. | N/A 9 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 8 in. | N/A 10 ft 7 in. | N/A 10 ft 11 in. | N/A 9 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 10 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 5 in. | N/A 9 ft 3 in. | N/A 9 ft 7 in. | N/A 9 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 9 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 11 in. | N/A 12 ft 10 in. | N/A 13 ft 6 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 5 in. | N/A 10 ft 4 in. | N/A 10 ft 8 in. | N/A 10 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 3 in. | N/A 9 ft 1 in. | N/A 9 ft 4 in. | N/A 10 ft 2 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 11 in. | N/A 10 ft 6 in. | N/A 11 ft 2 in. | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 3 in. | N/A 10 ft 2 in. | N/A 10 ft 6 in. | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 6 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 1 in. | N/A 8 ft 11 in. | N/A 9 ft 2 in. | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 5 in. | N/A 9 ft 1 in. | N/A 9 ft 8 in. | N/A 7 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 5 in. | N/A 9 ft 1 in. | N/A 9 ft 7 in. | N/A 7 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 7 ft 4 in. | N/A 8 ft 1 in. | N/A 8 ft 4 in. | N/A 7 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
Notes for Fully Braced Non-Composite Limiting Height |
N/A
|
|||||||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 7 in. | N/A 15 ft 0 in. | N/A 16 ft 5 in. | N/A 17 ft 0 in. | N/A 14 ft 3 in. | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 11 ft 0 in. | N/A 11 ft 11 in. | N/A 13 ft 1 in. | N/A 13 ft 6 in. | N/A 14 ft 3 in. | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 8 in. | N/A 10 ft 5 in. | N/A 11 ft 5 in. | N/A 11 ft 9 in. | N/A 12 ft 10 in. | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 13 ft 2 in. | N/A 13 ft 9 in. | N/A 14 ft 8 in. | N/A 11 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 8 in. | N/A 12 ft 10 in. | N/A 13 ft 3 in. | N/A 11 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 6 in. | N/A 10 ft 3 in. | N/A 11 ft 3 in. | N/A 11 ft 7 in. | N/A 11 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 5 in. | N/A 11 ft 11 in. | N/A 12 ft 9 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 8 in. | N/A 11 ft 8 in. | N/A 12 ft 1 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 3 in. | N/A 10 ft 2 in. | N/A 10 ft 6 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 11 in. | N/A 13 ft 7 in. | N/A 14 ft 7 in. | N/A 15 ft 5 in. | N/A 12 ft 4 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 0 in. | N/A 10 ft 10 in. | N/A 11 ft 10 in. | N/A 12 ft 3 in. | N/A 12 ft 4 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 9 in. | N/A 9 ft 5 in. | N/A 10 ft 4 in. | N/A 10 ft 8 in. | N/A 11 ft 8 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 5 in. | N/A 11 ft 11 in. | N/A 12 ft 9 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 8 in. | N/A 11 ft 8 in. | N/A 12 ft 1 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 7 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 3 in. | N/A 10 ft 2 in. | N/A 10 ft 6 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 11 in. | N/A 10 ft 4 in. | N/A 11 ft 0 in. | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 8 in. | N/A 10 ft 4 in. | N/A 10 ft 11 in. | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 5 in. | N/A 9 ft 3 in. | N/A 9 ft 7 in. | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 11 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 5 in. | N/A 11 ft 11 in. | N/A 12 ft 9 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 5 in. | N/A 10 ft 4 in. | N/A 10 ft 8 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 3 in. | N/A 9 ft 1 in. | N/A 9 ft 4 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 4 in. | N/A 9 ft 9 in. | N/A 10 ft 5 in. | N/A 8 ft 3 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 3 in. | N/A 9 ft 9 in. | N/A 10 ft 5 in. | N/A 8 ft 3 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 1 in. | N/A 8 ft 11 in. | N/A 9 ft 2 in. | N/A 8 ft 3 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 1 in. | N/A 8 ft 5 in. | N/A 9 ft 0 in. | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 1 in. | N/A 8 ft 5 in. | N/A 9 ft 0 in. | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 7 ft 4 in. | N/A 8 ft 1 in. | N/A 8 ft 4 in. | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
Notes for 48 Inch (in) O.C. Bracing Non-Composite Limiting Height |
N/A
|
|||||||||
Compliance |
N/A
TRAKLOC®’s ICC-ES Report # ESR-1464 is in compliance with:
|
|||||||||
United States (U.S.) and Foreign Patents |
N/A
The TRAKLOC® product line provided by ClarkDietrich® Building Systems is licensed under the following U.S. and Foreign Patents: U.S. Patent No. 7,223,043 U.S. Patent No. 7,594,311 U.S. Patent No. 8,061,099 U.S. Patent No. 8,074,416 Japan Patent No. 4934868 Japan Patent No. 5156889 Australia Patent No. 2006201344 Australia Patent No. 2005332657 |
|||||||||
TRAKLOC® Track |
N/A
TRAKLOC® track has two unique features. The most obvious feature of the TRAKLOC® track is the V-groove rolled into the flanges of the track to match the swaged ends of the TRAKLOC® stud. Next, are the dimples pressed into the center of the web. Together, the V-groove and the dimples provide a positive connection between stud and track without the need for mechanical fasteners. TRAKLOC® track standard length is 10'-0". Shorter lengths are available for non-standard conditions. |
|||||||||
Storage Requirements | N/A TRAKLOC® is a dynamic system consisting of two moving parts. To maintain the telescoping feature of this system, it is important to store TRAKLOC® studs indoors, free of excessive dust and airborne particulates. | |||||||||
Head-of-Wall Deflection Required ? | N/A Elevator Studs are not for deflection by themselves. However, deflection can be achieved by using MaxTrak® slotted deflection track or deep leg track with lateral bracing at the head of the wall. | |||||||||
Other Benefits Include |
N/A
|
|||||||||
Features and Benefits |
N/A
|
|||||||||
Addition Information |
N/A
TRAKLOC® stud without telescopic extension. Studs are fixed length and not adjustable and have a TRAKLOC® swaged end on both ends of the stud allowing the stud to be connected to the top and bottom track without fasteners.
|
|||||||||
Note |
N/A
For SI Units: 1 inch = 25.4 mm, 1 lb = 4.45 N, 1 ksi = 6.89 N/mm².
|
|||||||||
|