The HDS® Framing System is a high-performance, cost-effective, multipurpose, heavy-duty framing stud for headers, jambs, posts and built-up tube truss chords and webs. The superior strength and carrying capacity of the HDS® Framing System means higher performance with fewer members. It means eliminating box beam headers, nesting track and stud for posts and jambs, and eliminating multi-member built-up truss chords and webs. It also means improved finish quality by eliminating excessive material and screw head buildup around doors and windows.
Unit of Measure
Specifications
|
Unperforated Section Properties
|
Torsional Properties
|
Other Properties
|
Unperforated Bending Properties
|
Perforated Bending Properties
|
Effective Moment of Inertia
|
Construction Advantages
|
Note
Specifications
Brands |
N/A A-1 Alloys ClarkDietrich® HDS® |
Thickness |
N/A 12 gauge97 mil |
Design Thickness |
N/A 0.0451 in |
Tensile Strength Fy |
N/A 33 ksi |
Depth |
N/A 3-5/8 in |
Flange Size |
N/A 3 in |
Return |
N/A 1-1/16 in |
Double Return |
N/A 3/4 in |
Minimum Delivered Thickness |
N/A 0.0966 in |
Unperforated Section Properties
Area |
N/A 1.239 in² |
Weight |
N/A 4.22 lb/ft |
Gross Moment of Inertia About X-Axis (Ix) |
N/A 2.520 in4 |
Gross Section Modulus About X-Axis (Sx) |
N/A 1.390 in³ |
Gross Radius of Gyration About X-Axis (Rx) |
N/A 1.426 in |
Gross Moment of Inertia About Y-Axis (ly) |
N/A 1.645 in4 |
The Distance from the Web Centerline to the Center of Gravity (xbar) |
N/A 1.367 in |
Gross Section Modulus About Y-Axis (Sy) |
N/A 1.039 in³ |
Gross Radius of Gyration About Y-Axis (ry) |
N/A 1.152 in |
Torsional Properties
St. Venant Torsion Constant Torsional Properties (Jx1000) |
N/A 4.271 in4 |
Warping Torsion Constant (Cw) |
N/A 10.420 in6 |
Distance from Shear Center to the Centroid Along the Principal X-Axis (Xo) |
N/A -3.449 in |
Polar Radius of Gyration About the Centroidal Principal Axis (Ro) |
N/A 3.906 in |
Distance from Shear Center to the Centroid Along the Principal X-Axis/Polar Radius of Gyration About the Centroidal Principal Axis 1-(Xo/ro)2 |
N/A 0.220 Beta |
Other Properties
Maximum Unbraced Length to Attain Mxa (Lu) |
N/A 81 in |
Allowable Shear for Bending About X-Axis (Unperforated Vx) |
N/A 6.05 kips |
Allowable Shear for Bending About X-Axis (Perforated Vx) |
N/A 0.92 kips |
Allowable Shear for Bending About Y-Axis (Vy) |
N/A 9.71 kips |
Other Properties (Px)1 | N/A 1.97 kips |
Other Properties (Py)2 | N/A 4 kips |
Unperforated Bending Properties
Effective Section Modulus About X-Axis (Sxe) Unperforated Bending Properties |
N/A 1.390 in³ |
Allowable Moment About X-Axis (Mxa) Unperforated Bending Properties |
N/A 45805 in·lb |
Effective Section Modulus About X-Axis (Sye) Unperforated Bending Properties (Web in Ten.) |
N/A 1.039 in³ |
Allowable Moment About Y-Axis (Mya) Unperforated Bending Properties (Web in Ten.) |
N/A 39444 in·lb |
Effective Section Modulus About X-Axis (Sye) Unperforated Bending Properties (Web in Comp.) |
N/A 1.039 in³ |
Allowable Moment About Y-Axis (Mya) Unperforated Bending Properties (Web in Comp.) |
N/A 33711 in·lb |
Perforated Bending Properties
Effective Section Modulus About X-Axis (Sxe) Perforated Bending Properties |
N/A 1.375 in³ |
Allowable Moment About X-Axis (Mxa) Perforated Bending Properties |
N/A 45285 in·lb |
Effective Section Modulus About X-Axis (Sye) Perforated Bending Properties (Web in Ten.) |
N/A 0.820 in³ |
Allowable Moment About Y-Axis (Mya) Perforated Bending Properties (Web in Ten.) |
N/A 31127 in·lb |
Effective Section Modulus About X-Axis (Sye) Perforated Bending Properties (Web in Comp.) |
N/A 0.820 in³ |
Allowable Moment About Y-Axis (Mya) Perforated Bending Properties (Web in Comp.) |
N/A 26602 in·lb |
Effective Moment of Inertia
Effective Moment of Inertia About X-Axis for Deflection Calculations (lxe) |
N/A 2.520 in4 |
Effective Moment of Inertia About Y-Axis for Deflection Calculations (Web in Ten. (lye)) |
N/A 1.645 in4 |
Effective Moment of Inertia About Y-Axis for Deflection Calculations (Web in Comp. (lye)) |
N/A 1.645 in4 |
Construction Advantages
Construction Advantages |
N/A
|
- 1 For members having a web depth of less than 8" and also having a thickness less than 97 mil, allowable web crippling per AISI Standard for CFS Wall Stud Design 2004. This value assumes the web resists web crippling and the HDS is nested in track having the same thickness. For other members, allowable end one flange web crippling per AISI NASPEC, 2001 with 2004 supplement. Both calculation procedures use a bearing length of 1-1/4".
- 2 Allowable end one flange web crippling per AISI NASPEC, 2001 w/2004 supplement. This value assumes 2 flanges resist web crippling for a bearing length of 1-1/4".