The HDS® Framing System is a high-performance, cost-effective, multipurpose, heavy-duty framing stud for headers, jambs, posts and built-up tube truss chords and webs. The superior strength and carrying capacity of the HDS® Framing System means higher performance with fewer members. It means eliminating box beam headers, nesting track and stud for posts and jambs, and eliminating multi-member built-up truss chords and webs. It also means improved finish quality by eliminating excessive material and screw head buildup around doors and windows.
Unit of Measure
Specifications
|
Unperforated Section Properties
|
Torsional Properties
|
Other Properties
|
Unperforated Bending Properties
|
Perforated Bending Properties
|
Effective Moment of Inertia
|
Construction Advantages
|
Note
Specifications
Brands |
N/A A-1 Alloys ClarkDietrich® HDS® |
Thickness |
N/A 14 gauge68 mil |
Design Thickness |
N/A 0.1017 in |
Tensile Strength Fy |
N/A 50 ksi |
Depth |
N/A 6 in |
Flange Size |
N/A 3 in |
Return |
N/A 2-1/4 in |
Double Return |
N/A 3/4 in |
Minimum Delivered Thickness |
N/A 0.0677 in |
Unperforated Section Properties
Area |
N/A 1.369 in² |
Weight |
N/A 4.66 lb/ft |
Gross Moment of Inertia About X-Axis (Ix) |
N/A 12.23 in4 |
Gross Section Modulus About X-Axis (Sx) |
N/A 3.058 in³ |
Gross Radius of Gyration About X-Axis (Rx) |
N/A 2.989 in |
Gross Moment of Inertia About Y-Axis (ly) |
N/A 2.193 in4 |
The Distance from the Web Centerline to the Center of Gravity (xbar) |
N/A 1.265 in |
Gross Section Modulus About Y-Axis (Sy) |
N/A 1.291 in³ |
Gross Radius of Gyration About Y-Axis (ry) |
N/A 1.266 in |
Torsional Properties
St. Venant Torsion Constant Torsional Properties (Jx1000) |
N/A 2.317 in4 |
Warping Torsion Constant (Cw) |
N/A 62.225 in6 |
Distance from Shear Center to the Centroid Along the Principal X-Axis (Xo) |
N/A -3.391 in |
Polar Radius of Gyration About the Centroidal Principal Axis (Ro) |
N/A 4.694 in |
Distance from Shear Center to the Centroid Along the Principal X-Axis/Polar Radius of Gyration About the Centroidal Principal Axis 1-(Xo/ro)2 |
N/A 0.478 Beta |
Other Properties
Maximum Unbraced Length to Attain Mxa (Lu) |
N/A 90 in |
Allowable Shear for Bending About X-Axis (Unperforated Vx) |
N/A 4.21 kips |
Allowable Shear for Bending About X-Axis (Perforated Vx) |
N/A 3.36 kips |
Allowable Shear for Bending About Y-Axis (Vy) |
N/A 7.06 kips |
Other Properties (Px)1 | N/A 0.94 kips |
Other Properties (Py)2 | N/A 2.08 kips |
Unperforated Bending Properties
Effective Section Modulus About X-Axis (Sxe) Unperforated Bending Properties |
N/A 2.946 in³ |
Allowable Moment About X-Axis (Mxa) Unperforated Bending Properties |
N/A 88217 in·lb |
Effective Section Modulus About X-Axis (Sye) Unperforated Bending Properties (Web in Ten.) |
N/A 1.265 in³ |
Allowable Moment About Y-Axis (Mya) Unperforated Bending Properties (Web in Ten.) |
N/A 41554 in·lb |
Effective Section Modulus About X-Axis (Sye) Unperforated Bending Properties (Web in Comp.) |
N/A 0.874 in³ |
Allowable Moment About Y-Axis (Mya) Unperforated Bending Properties (Web in Comp.) |
N/A 26153 in·lb |
Perforated Bending Properties
Effective Section Modulus About X-Axis (Sxe) Perforated Bending Properties |
N/A 2.946 in³ |
Allowable Moment About X-Axis (Mxa) Perforated Bending Properties |
N/A 88217 in·lb |
Effective Section Modulus About X-Axis (Sye) Perforated Bending Properties (Web in Ten.) |
N/A 1.237 in³ |
Allowable Moment About Y-Axis (Mya) Perforated Bending Properties (Web in Ten.) |
N/A 40635 in·lb |
Effective Section Modulus About X-Axis (Sye) Perforated Bending Properties (Web in Comp.) |
N/A 0.700 in³ |
Allowable Moment About Y-Axis (Mya) Perforated Bending Properties (Web in Comp.) |
N/A 20957 in·lb |
Effective Moment of Inertia
Effective Moment of Inertia About X-Axis for Deflection Calculations (lxe) |
N/A 12.23 in4 |
Effective Moment of Inertia About Y-Axis for Deflection Calculations (Web in Ten. (lye)) |
N/A 2.193 in4 |
Effective Moment of Inertia About Y-Axis for Deflection Calculations (Web in Comp. (lye)) |
N/A 1.690 in4 |
Construction Advantages
Construction Advantages |
N/A
|
- 1 For members having a web depth of less than 8" and also having a thickness less than 97 mil, allowable web crippling per AISI Standard for CFS Wall Stud Design 2004. This value assumes the web resists web crippling and the HDS is nested in track having the same thickness. For other members, allowable end one flange web crippling per AISI NASPEC, 2001 with 2004 supplement. Both calculation procedures use a bearing length of 1-1/4".
- 2 Allowable end one flange web crippling per AISI NASPEC, 2001 w/2004 supplement. This value assumes 2 flanges resist web crippling for a bearing length of 1-1/4".