Items |
250TLE125-18 TRAKLOC® 0.0188 Inch (in) Design Thickness Elevator Stud |
250TLE125-24 TRAKLOC® 0.0250 Inch (in) Design Thickness Elevator Stud |
250TLE125-30 TRAKLOC® 0.0312 Inch (in) Design Thickness Elevator Stud |
250TLE125-33 TRAKLOC® 0.0346 Inch (in) Design Thickness Elevator Stud |
362TLE125-18 TRAKLOC® 0.0188 Inch (in) Design Thickness Elevator Stud |
|||||
Description | N/A The two-piece elevator studs arrive in a compressed position to accommodate stocking in a building elevator and then can be extended (telescoped) to the required length at point of installation. This reduces the cost of stocking long studs on floors accessible only by elevators and stairways. | |||||||||
Brands | N/A A-1 Alloys ClarkDietrich® TRAKLOC® | |||||||||
Design Thickness | N/A 0.0188 in | N/A 0.0250 in | N/A 0.0312 in | N/A 0.0346 in | N/A 0.0188 in | |||||
Yield Strength | N/A 33 ksi | N/A 57 ksi | N/A 33 ksi | N/A 33 ksi | N/A 33 ksi | |||||
Area | N/A 0.099 in² | N/A 0.130 in² | N/A 0.161 in² | N/A 0.178 in² | N/A 0.120 in² | |||||
Weight | N/A 0.34 lb/ft | N/A 0.44 lb/ft | N/A 0.55 lb/ft | N/A 0.61 lb/ft | N/A 0.41 lb/ft | |||||
Gross Section Properties (lx) | N/A 0.098 in4 | N/A 0.128 in4 | N/A 0.156 in4 | N/A 0.170 in4 | N/A 0.234 in4 | |||||
Gross Section Properties (Sx) | N/A 0.080 in³ | N/A 0.104 in³ | N/A 0.128 in³ | N/A 0.140 in³ | N/A 0.131 in³ | |||||
Gross Section Properties (Rx)1 | N/A 0.997 in | N/A 0.990 in | N/A 0.982 in | N/A 0.978 in | N/A 1.398 in | |||||
Gross Section Properties (ly) | N/A 0.019 in4 | N/A 0.025 in4 | N/A 0.031 in4 | N/A 0.034 in4 | N/A 0.022 in4 | |||||
Gross Section Properties (Ry) | N/A 0.444 in | N/A 0.441 in | N/A 0.438 in | N/A 0.436 in | N/A 0.428 in | |||||
Effective Section Properties at Tensile Strength (Fy) (Ae) | N/A 0.056 in² | N/A 0.066 in² | N/A 0.113 in² | N/A 0.116 in² | N/A 0.056 in² | |||||
Effective Section Properties at Tensile Strength (Fy) (lx) | N/A 0.082 in4 | N/A 0.115 in4 | N/A 0.163 in4 | N/A 0.171 in4 | N/A 0.204 in4 | |||||
Effective Section Properties at Tensile Strength (Fy) (Sx) | N/A 0.059 in³ | N/A 0.071 in³ | N/A 0.125 in³ | N/A 0.143 in³ | N/A 0.084 in³ | |||||
Effective Section Properties at Tensile Strength (Fy) (Mal) | N/A 1165 in·lb | N/A 2423 in·lb | N/A 2475 in·lb | N/A 2824 in·lb | N/A 1661 in·lb | |||||
Effective Section Properties at Tensile Strength (Fy) (Mad)2 | N/A 1123 in·lb | N/A 2297 in·lb | N/A 2515 in·lb | N/A 3047 in·lb | N/A 1687 in·lb | |||||
Effective Section Properties at Tensile Strength (Fy) (Vag) | N/A 256 lb | N/A 609 lb | N/A 832 lb | N/A 961 lb | N/A 172 lb | |||||
Effective Section Properties at Tensile Strength (Fy) (Vanet) | N/A 197 lb | N/A 346 lb | N/A 372 lb | N/A 384 lb | N/A 164 lb | |||||
Stud/Track End Reaction (Rx) | N/A 39 lb | N/A 108 lb | N/A 137 lb | N/A 149 lb | N/A 47 lb | |||||
Torsional Properties (Jx1000) | N/A 0.0116 in4 | N/A 0.0271 in4 | N/A 0.0523 in4 | N/A 0.0710 in4 | N/A 0.0141 in4 | |||||
Torsional Properties (Cw) | N/A 0.026 in6 | N/A 0.034 in6 | N/A 0.041 in6 | N/A 0.044 in6 | N/A 0.058 in6 | |||||
Torsional Properties (Xo) | N/A -0.946 in | N/A -0.940 in | N/A -0.934 in | N/A -0.931 in | N/A -0.823 in | |||||
Torsional Properties (m) | N/A 0.568 in | N/A 0.564 in | N/A 0.561 in | N/A 0.559 in | N/A 0.511 in | |||||
Torsional Properties (Ro) | N/A 1.445 in | N/A 1.435 in | N/A 1.425 in | N/A 1.419 in | N/A 1.677 in | |||||
Torsional Properties (ß) | N/A 0.571 Beta | N/A 0.570 Beta | N/A 0.570 Beta | N/A 0.570 Beta | N/A 0.759 Beta | |||||
Length (Lu) | N/A 30.1 in | N/A 22.8 in | N/A 30.0 in | N/A 28.5 in | N/A 29.6 in | |||||
Width | N/A 2-1/2 in | N/A 2-1/2 in | N/A 2-1/2 in | N/A 2-1/2 in | N/A 3-5/8 in | |||||
Spacing | N/A 12 in16 in24 in | |||||||||
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 17 ft 0 in. | N/A 18 ft 9 in. | N/A 20 ft 0 in. | N/A 20 ft 0 in. | N/A 20 ft 7 in. | |||||
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 15 ft 1 in. | N/A 15 ft 9 in. | N/A 16 ft 9 in. | N/A 16 ft 9 in. | N/A 17 ft 2 in. | |||||
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 11 in. | N/A 13 ft 8 in. | N/A 14 ft 7 in. | N/A 14 ft 7 in. | N/A 14 ft 6 in. | |||||
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 14 ft 11 in. | N/A 16 ft 5 in. | N/A 17 ft 6 in. | N/A 17 ft 6 in. | N/A 18 ft 0 in. | |||||
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 13 ft 2 in. | N/A 13 ft 9 in. | N/A 14 ft 7 in. | N/A 14 ft 7 in. | N/A 15 ft 0 in. | |||||
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 11 ft 4 in. | N/A 12 ft 0 in. | N/A 12 ft 8 in. | N/A 12 ft 8 in. | N/A 12 ft 8 in. | |||||
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 13 ft 6 in. | N/A 14 ft 11 in. | N/A 15 ft 11 in. | N/A 15 ft 11 in. | N/A 16 ft 1 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 0 in. | N/A 12 ft 6 in. | N/A 13 ft 3 in. | N/A 13 ft 3 in. | N/A 13 ft 7 in. | |||||
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 3 in. | N/A 10 ft 11 in. | N/A 11 ft 7 in. | N/A 11 ft 7 in. | N/A 11 ft 5 in. | |||||
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 15 ft 6 in. | N/A 17 ft 1 in. | N/A 18 ft 2 in. | N/A 18 ft 2 in. | N/A 18 ft 9 in. | |||||
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 13 ft 9 in. | N/A 14 ft 4 in. | N/A 15 ft 2 in. | N/A 15 ft 2 in. | N/A 15 ft 7 in. | |||||
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 11 ft 9 in. | N/A 12 ft 5 in. | N/A 13 ft 3 in. | N/A 13 ft 3 in. | N/A 13 ft 2 in. | |||||
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 13 ft 6 in. | N/A 14 ft 11 in. | N/A 15 ft 11 in. | N/A 15 ft 11 in. | N/A 16 ft 1 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 12 ft 0 in. | N/A 12 ft 6 in. | N/A 13 ft 3 in. | N/A 13 ft 3 in. | N/A 13 ft 7 in. | |||||
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 3 in. | N/A 10 ft 11 in. | N/A 11 ft 7 in. | N/A 11 ft 7 in. | N/A 11 ft 5 in. | |||||
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 12 ft 0 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 13 ft 6 in. | N/A 14 ft 5 in. | N/A 14 ft 5 in. | N/A 13 ft 11 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 11 in. | N/A 11 ft 4 in. | N/A 12 ft 1 in. | N/A 12 ft 1 in. | N/A 12 ft 4 in. | |||||
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 9 ft 0 in. | N/A 9 ft 11 in. | N/A 10 ft 6 in. | N/A 10 ft 6 in. | N/A 10 ft 2 in. | |||||
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 13 ft 6 in. | N/A 14 ft 11 in. | N/A 15 ft 11 in. | N/A 15 ft 11 in. | N/A 16 ft 1 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 12 ft 0 in. | N/A 12 ft 6 in. | N/A 13 ft 3 in. | N/A 13 ft 3 in. | N/A 13 ft 7 in. | |||||
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 10 ft 3 in. | N/A 10 ft 11 in. | N/A 11 ft 7 in. | N/A 11 ft 7 in. | N/A 11 ft 5 in. | |||||
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 11 ft 4 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 13 ft 0 in. | N/A 13 ft 11 in. | N/A 13 ft 11 in. | N/A 13 ft 2 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 10 ft 6 in. | N/A 10 ft 11 in. | N/A 11 ft 7 in. | N/A 11 ft 7 in. | N/A 11. ft 11 in. | |||||
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 6 in. | N/A 9 ft 4 in. | N/A 10 ft 1 in. | N/A 10 ft 1 in. | N/A 9 ft 8 in. | |||||
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 9 ft 10 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | N/A 11 ft 10 in. | N/A 12 ft 7 in. | N/A 12 ft 7 in. | N/A 11 ft 5 in. (Adjacent to the height value indicates that flexural stress controls the allowable wall height.) | |||||
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 9 ft 5 in. | N/A 9 ft 11 in. | N/A 10 ft 6 in. | N/A 10 ft 6 in. | N/A 10 ft 8 in. | |||||
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A | N/A 7 ft 10 in. | N/A 8 ft 9 in. | N/A 8 ft 9 in. | N/A 8 ft 7 in. | |||||
Notes for Composite Limiting Height |
N/A
|
|||||||||
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 3 in. | N/A 14 ft 5 in. | N/A 16 ft 3 in. | N/A 16 ft 6 in. | N/A 14 ft 11 in. | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 3 in. | N/A 11 ft 6 in. | N/A 12 ft 10 in. | N/A 13 ft 1 in. | N/A 13 ft 10 in. | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 0 in. | N/A 10 ft 0 in. | N/A 11 ft 3 in. | N/A 11 ft 5 in. | N/A 12 ft 1 in. | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 0 in. | N/A 14 ft 2 in. | N/A 14 ft 10 in. | N/A 15 ft 10 in. | N/A 12 ft 2 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 0 in. | N/A 11 ft 3 in. | N/A 12 ft 8 in. | N/A 12 ft 10 in. | N/A 12 ft 2 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 10 in. | N/A 9 ft 10 in. | N/A 11 ft 1 in. | N/A 11 ft 3 in. | N/A 11 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 12 ft 4 in. | N/A 12 ft 10 in. | N/A 13 ft 9 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 3 in. | N/A 11 ft 6 in. | N/A 11 ft 8 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 11 in. | N/A 10 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 7 in. | N/A 13 ft 1 in. | N/A 14 ft 9 in. | N/A 15 ft 0 in. | N/A 12 ft 11 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 9 ft 4 in. | N/A 10 ft 5 in. | N/A 11 ft 8 in. | N/A 11 ft 11 in. | N/A 12 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 2 in. | N/A 9 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 5 in. | N/A 11 ft 0 in. | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 12 ft 4 in. | N/A 12 ft 10 in. | N/A 13 ft 9 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 3 in. | N/A 11 ft 6 in. | N/A 11 ft 8 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 11 in. | N/A 10 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 6 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 9 in. | N/A 11 ft 1 in. | N/A 11 ft 11 in. | N/A 9 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 6 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 4 in. | N/A 10 ft 5 in. | N/A 10 ft 7 in. | N/A 9 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 2 in. | N/A 9 ft 2 in. | N/A 9 ft 3 in. | N/A 9 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 6 in. | N/A 12 ft 10 in. | N/A 13 ft 1 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 2 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 5 in. | N/A 10 ft 6 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 1 in. | N/A 7 ft 11 in. | N/A 8 ft 11 in. | N/A 9 ft 1 in. | N/A 9 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 1 in. | N/A 10 ft 6 in. | N/A 11 ft 2 in. | N/A 8 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 11 in. | N/A 10 ft 1 in. | N/A 10 ft 3 in. | N/A 8 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 7 ft 10 in. | N/A 8 ft 9 in. | N/A 8 ft 11 in. | N/A 8 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 9 in. | N/A 9 ft 1 in. | N/A 9 ft 8 in. | N/A 7 ft 5 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 2 in. | N/A 9 ft 1 in. | N/A 9 ft 3 in. | N/A 7 ft 5 in. (Web stiffeners are required at the stud/track connection.) | |||||
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 7 ft 1 in. | N/A 8 ft 0 in. | N/A 8 ft 1 in. | N/A 7 ft 5 in. (Web stiffeners are required at the stud/track connection.) | |||||
Notes for Fully Braced Non-Composite Limiting Height |
N/A
|
|||||||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 12 ft 3 in. | N/A 14 ft 5 in. | N/A 16 ft 3 in. | N/A 16 ft 6 in. | N/A 14 ft 3 in. | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 3 in. | N/A 11 ft 6 in. | N/A 12 ft 10 in. | N/A 13 ft 1 in. | N/A 13 ft 10 in. | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 9 ft 0 in. | N/A 10 ft 0 in. | N/A 11 ft 3 in. | N/A 11 ft 5 in. | N/A 12 ft 1 in. | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 0 in. | N/A 13 ft 2 in. | N/A 13 ft 9 in. | N/A 14 ft 8 in. | N/A 11 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 10 ft 0 in. | N/A 11 ft 3 in. | N/A 12 ft 8 in. | N/A 12 ft 10 in. | N/A 11 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 10 in. | N/A 9 ft 10 in. | N/A 11 ft 1 in. | N/A 11 ft 3 in. | N/A 11 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 5 in. | N/A 11 ft 11 in. | N/A 12 ft 9 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 3 in. | N/A 11 ft 6 in. | N/A 11 ft 8 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing | N/A 8 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 11 in. | N/A 10 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 10 ft 7 in. | N/A 13 ft 1 in. | N/A 14 ft 7 in. | N/A 15 ft 0 in. | N/A 12 ft 4 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 9 ft 4 in. | N/A 10 ft 5 in. | N/A 11 ft 8 in. | N/A 11 ft11 in. | N/A 12 ft 4 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 2 in. | N/A 9 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 5 in. | N/A 11 ft 0 in. | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 5 in. | N/A 11 ft 11 in. | N/A 12 ft 9 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 10 ft 3 in. | N/A 11 ft 6 in. | N/A 11 ft 8 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 8 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 11 in. | N/A 10 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 6 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 11 in. | N/A 10 ft 4 in. | N/A 11 ft 0 in. | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 6 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 4 in. | N/A 10 ft 4 in. | N/A 10 ft 7 in. | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing | N/A 7 ft 3 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 2 in. | N/A 9 ft 2 in. | N/A 9 ft 3 in. | N/A 8 ft 9 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 8 in. (Web stiffeners are required at the stud/track connection.) | N/A 11 ft 5 in. | N/A 11 ft 11 in. | N/A 12 ft 9 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 8 ft 2 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 1 in. | N/A 10 ft 3 in. | N/A 10 ft 5 in. | N/A 10 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 1 in. | N/A 7 ft 11 in. | N/A 8 ft 11 in. | N/A 9 ft 1 in. | N/A 9 ft 7 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 9 ft 4 in. | N/A 9 ft 9 in. | N/A 10 ft 5 in. | N/A 8 ft 3 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 11 in. | N/A 9 ft 9 in. | N/A 10 ft 3 in. | N/A 8 ft 3 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 7 ft 0 in. (Web stiffeners are required at the stud/track connection.) | N/A 7 ft 10 in. | N/A 8 ft 9 in. | N/A 8 ft 11 in. | N/A 8 ft 3 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 1 in. | N/A 8 ft 5 in. | N/A 9 ft 0 in. | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 8 ft 1 in. | N/A 8 ft 5 in. | N/A 9 ft 0 in. | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing | N/A 6 ft 1 in. (Web stiffeners are required at the stud/track connection.) | N/A 7 ft 1 in. | N/A 8 ft 0 in. | N/A 8 ft 1 in. | N/A 7 ft 1 in. (Web stiffeners are required at the stud/track connection.) | |||||
Notes for 48 Inch (in) O.C. Bracing Non-Composite Limiting Height |
N/A
|
|||||||||
Compliance |
N/A
TRAKLOC®’s ICC-ES Report # ESR-1464 is in compliance with:
|
|||||||||
United States (U.S.) and Foreign Patents |
N/A
The TRAKLOC® product line provided by ClarkDietrich® Building Systems is licensed under the following U.S. and Foreign Patents: U.S. Patent No. 7,223,043 U.S. Patent No. 7,594,311 U.S. Patent No. 8,061,099 U.S. Patent No. 8,074,416 Japan Patent No. 4934868 Japan Patent No. 5156889 Australia Patent No. 2006201344 Australia Patent No. 2005332657 |
|||||||||
TRAKLOC® Track |
N/A
TRAKLOC® track has two unique features. The most obvious feature of the TRAKLOC® track is the V-groove rolled into the flanges of the track to match the swaged ends of the TRAKLOC® stud. Next, are the dimples pressed into the center of the web. Together, the V-groove and the dimples provide a positive connection between stud and track without the need for mechanical fasteners. TRAKLOC® track standard length is 10'-0". Shorter lengths are available for non-standard conditions. |
|||||||||
Storage Requirements | N/A TRAKLOC® is a dynamic system consisting of two moving parts. To maintain the telescoping feature of this system, it is important to store TRAKLOC® studs indoors, free of excessive dust and airborne particulates. | |||||||||
Head-of-Wall Deflection Required ? | N/A Elevator Studs are not for deflection by themselves. However, deflection can be achieved by using MaxTrak® slotted deflection track or deep leg track with lateral bracing at the head of the wall. | |||||||||
Other Benefits Include |
N/A
|
|||||||||
Features and Benefits |
N/A
|
|||||||||
Addition Information |
N/A
TRAKLOC® non-load bearing interior wall system is Intertek Warnock Hersey Design Listed and approved for use in both one and two-hour fire-rated head-of-wall assemblies requiring deflection in accordance with ASTM E119 and ASTM E1966. Intertek Design Listings Nos. on inside back cover.
|
|||||||||
Note |
N/A
For SI Units: 1 inch = 25.4 mm, 1 lb = 4.45 N, 1 ksi = 6.89 N/mm².
|
|||||||||
|