Design Thickness |
N/A 0.0346 in |
Yield Strength |
N/A 33 ksi |
Area |
N/A 0.217 in² |
Weight |
N/A 0.74 lb/ft |
Gross Section Properties (lx) |
N/A 0.412 in4 |
Gross Section Properties (Sx) |
N/A 0.232 in³ |
Gross Section Properties (Rx)1 | N/A 1.378 in |
Gross Section Properties (ly) |
N/A 0.038 in4 |
Gross Section Properties (Ry) |
N/A 0.420 in |
Effective Section Properties at Tensile Strength (Fy) (Ae) |
N/A 0.117 in² |
Effective Section Properties at Tensile Strength (Fy) (lx) |
N/A 0.394 in4 |
Effective Section Properties at Tensile Strength (Fy) (Sx) |
N/A 0.208 in³ |
Effective Section Properties at Tensile Strength (Fy) (Mal) |
N/A 4116 in·lb |
Effective Section Properties at Tensile Strength (Fy) (Mad)2 | N/A 4404 in·lb |
Effective Section Properties at Tensile Strength (Fy) (Vag) |
N/A 1024 lb |
Effective Section Properties at Tensile Strength (Fy) (Vanet) |
N/A 512 lb |
Stud/Track End Reaction (Rx) |
N/A 133 lb |
Torsional Properties (Jx1000) |
N/A 0.0866 in4 |
Torsional Properties (Cw) |
N/A 0.100 in6 |
Torsional Properties (Xo) |
N/A -0.808 in |
Torsional Properties (m) |
N/A 0.503 in |
Torsional Properties (Ro) |
N/A 1.651 in |
Torsional Properties (ß) |
N/A 0.761 Beta |
Length (Lu) |
N/A 27.9 in |
Width |
N/A 3-5/8 in |
Spacing |
N/A 12 in16 in24 in |
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 25 ft 4 in. |
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 20 ft 1 in. |
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 17 ft 7 in. |
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 22 ft 2 in. |
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 17 ft 7 in. |
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 15 ft 4 in. |
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 20 ft 1 in. |
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 15 ft 11 in. |
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 13 ft 11 in. |
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 23 ft 0 in. |
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 18 ft 3 in. |
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 15 ft 11 in. |
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 20 ft 1 in. |
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 15 ft 11 in. |
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 13 ft 11 in. |
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 18 ft 3 in. |
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 14 ft 6 in. |
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 12 ft 8 in. |
Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 20 ft 1 in. |
Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 15 ft 11 in. |
Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 13 ft 11 in. |
Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 17 ft 7 in. |
Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 13 ft 11 in. |
Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 12 ft 1 in. |
Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 15 ft 11 in. |
Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 12 ft 8 in. |
Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 10 ft 11 in. |
Notes for Composite Limiting Height |
N/A
|
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 21 ft 9 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 17 ft 3 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 15 ft 1 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 19 ft 2 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 17 ft 0 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 14 ft 10 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 16 ft 7 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 15 ft 5 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 13 ft 6 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 19 ft 9 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 15 ft 8 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 13 ft 9 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 16 ft 7 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 15 ft 5 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 13 ft 6 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 14 ft 4 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 14 ft 0 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 12 ft 3 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 16 ft 7 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 13 ft 9 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 12 ft 0 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 13 ft 6 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 13 ft 6 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 11 ft 9 in. |
Fully Braced Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 11 ft 9 in. |
Fully Braced Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 11 ft 9 in. |
Fully Braced Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 10 ft 9 in. |
Notes for Fully Braced Non-Composite Limiting Height |
N/A
|
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 21 ft 6 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 17 ft 3 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 15 ft 1 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 17 ft 7 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 17 ft 0 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 14 ft 10 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 15 ft 3 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 15 ft 3 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 12 Inch (in) Spacing |
N/A 13 ft 6 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 18 ft 8 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 15 ft 8 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 13 ft 9 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 15 ft 3 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 15 ft 3 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 13 ft 6 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 13 ft 2 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 13 ft 2 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 16 Inch (in) Spacing |
N/A 12 ft 3 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 15 ft 3 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 13 ft 9 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 12 ft 0 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 12 ft 5 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 12 ft 5 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 7.5 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 11 ft 9 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/120) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 10 ft 9 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/240) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 10 ft 9 in. |
48 Inch (in) O.C. Bracing Non-Composite Limiting Height (L/360) at 10 Pounds Per Square Foot (PSF) Pressure and 24 Inch (in) Spacing |
N/A 10 ft 9 in. |
Notes for 48 Inch (in) O.C. Bracing Non-Composite Limiting Height |
N/A
|
Compliance |
N/A
TRAKLOC®’s ICC-ES Report # ESR-1464 is in compliance with:
|
United States (U.S.) and Foreign Patents |
N/A
The TRAKLOC® product line provided by ClarkDietrich® Building Systems is licensed under the following U.S. and Foreign Patents: U.S. Patent No. 7,223,043 U.S. Patent No. 7,594,311 U.S. Patent No. 8,061,099 U.S. Patent No. 8,074,416 Japan Patent No. 4934868 Japan Patent No. 5156889 Australia Patent No. 2006201344 Australia Patent No. 2005332657 |
TRAKLOC® Track |
N/A
TRAKLOC® track has two unique features. The most obvious feature of the TRAKLOC® track is the V-groove rolled into the flanges of the track to match the swaged ends of the TRAKLOC® stud. Next, are the dimples pressed into the center of the web. Together, the V-groove and the dimples provide a positive connection between stud and track without the need for mechanical fasteners. TRAKLOC® track standard length is 10'-0". Shorter lengths are available for non-standard conditions. |
Storage Requirements |
N/A TRAKLOC® is a dynamic system consisting of two moving parts. To maintain the telescoping feature of this system, it is important to store TRAKLOC® studs indoors, free of excessive dust and airborne particulates. |
Head-of-Wall Deflection Required ? |
N/A Elevator Studs are not for deflection by themselves. However, deflection can be achieved by using MaxTrak® slotted deflection track or deep leg track with lateral bracing at the head of the wall. |
Other Benefits Include |
N/A
|
Features and Benefits |
N/A
|
Addition Information |
N/A
TRAKLOC® non-load bearing interior wall system is Intertek Warnock Hersey Design Listed and approved for use in both one and two-hour fire-rated head-of-wall assemblies requiring deflection in accordance with ASTM E119 and ASTM E1966. Intertek Design Listings Nos. on inside back cover.
|
Note |
N/A
For SI Units: 1 inch = 25.4 mm, 1 lb = 4.45 N, 1 ksi = 6.89 N/mm².
|